How often to replace tubing: If tubing slides on and off easily when you’re not moving around, or when milk or moisture gets into the tubing of a closed system pump.īelow is a quick reference guide to when to replace pump parts: Medela tubing can be washed if this happens. Spectra tubing, for example, should be replaced immediately if breast milk or moisture gets into the pump because it can damage the motor. How tubing should be treated varies depending on the pump manufacturer. How often to replace breast shields: Every 6 months, or immediately if you notice tears or cracks.Ĭonnects your pump motor to your pump parts and bottles. This buildup can reduce the effectiveness of the pump. Sometimes residue builds up on these pump parts, especially in hard to reach spots on connectors. Other pumps (like Medela) have separate pieces. Some pumps (like Spectra) just have one piece that is both a breast shield and connector.

#SPECTRA S1 PARTS HOW TO#

More info on how to find the correct size here.)Ĭonnectors are the pieces that connect your breast shields to your valves, tubing, and backflow protectors. (Note that you may need a different size than the one that comes with your pump. If you pump less than 3 times per day, replace every 6 months.Īre also called flanges, and are the parts that attach to your breasts. How often to replace backflow protectors: If you pump 3 or more times per day, replace backflow protectors every 3 months. Medela pumps, for example, do not have them, while Spectra pumps do. Not all pumps have separate backflow protectors. Prevent breast milk and moisture from entering your tubing. If you pump less than 3 times per day, replace every 2 months. How often to replace valve membranes: If you pump 3 or more times per day, replace valve membranes every 2-4 weeks. Valve membranes have two pieces – the yellow piece, which is the valve, and the white piece, which is the membrane. (Spectra pumps generally come with duck valves and some Medela pumps come with valve membranes.) Instead, duck valves should be washed in hot, soapy water with a clean brush. Note: To extend the life of your valves, Spectra recommends avoiding washing valves in the dishwasher.

spectra s1 parts

If you pump less than 3 times per day, replace every 2-3 months.

spectra s1 parts

How often to replace duck valves: If you pump 3 or more times per day, replace duck valves every month. If your breast pump is starting to lose suction, replacing the valves is one of the first things that you should try. (also called duckbills) are made of silicone, and they stretch and release each time the pump motor pulls at the valve, creating the suction necessary to remove breast milk from your breasts. (Specific recommendations for some of the popular breast pump manufacturers are included at the bottom of this post.) However, it’s a good idea to check with your breast pump manufacturer to confirm how frequently they suggest replacement, as this can differ between brands. Below is a breakdown of how often each individual pump part should be replaced.īelow are general timeframes for replacing each pump part. The frequency with which you’ll need to replace your pump parts depends on the piece as well as how often you pump. I only recommend products I love! More info here. This post may contain affiliate links, which means that if you click through and make a purchase, I’ll be compensated at no additional cost to you.

spectra s1 parts

Here’s how often you should replace your breast pump parts to avoid issues with your milk supply. This can affect your pump’s suction, potentially causing a decrease in milk production. Over time, breast pump parts experience wear and tear.